Checklist: don’t forget the maintenance of your AKIMist®E before the holiday closing!
Maintenance tips for your Dry Fog humidifier AKIMist®”E” before closing during the holidays
During the winter and summer holidays, some factories close for few weeks, leaving all the equipment turned off. If you have installed our Dry Fog humidifier AKIMist®”E” (or any other humidification system that is connected to a water pipe), you need to make sure you don’t leave stagnated water that could get contaminated and risk legionella or other bacterial contamination issue.
So before your holiday shutdown, don’t forget to complete this maintenance checklist to prevent any issue with your humidifier when you return.
Maintenance before the factory closes
- Keep the water supply closed an flush all the remaining water in AKIMist®”E” by spraying until there is no more fog.
- Close the drainage valve.
- Flush the water pipes toward the drainage and make them empty.
- Close the water supply.
Clean the AKIMist®”E” nozzles tip
You can take the opportunity to clean the nozzle tips of the AKIMist®”E” to remove foreign particles or clogging (if needed).
How to clean the nozzle tip
As your system is already off, you can directly remove the nozzles from the AKIMist®”E” body. For a visual explanation of this maintenance process, please check the video below.
If your system is still running, please turn off the air valve from the AKIMist®”E” before removing the nozzles.
- Detach the nozzles by turning them counter-clockwise from the humidifier’s body
- Unscrew the nozzle to separate the tip and the nozzle’s body
- Pull the tip of the nozzle to detach it
- Use the needle from our cleaning kit to push through the nozzle tip and unclog it
- Use the brush from our cleaning kit to clean the inside and outside of the nozzle body
- Reinsert the nozzle tip to the body and screw back to reattach them together
- Reattach the full nozzle to the AKIMist®”E” body, turn the nozzles clockwise
What to do when you come back?
- Open the drainage valve and the water supply.
- Flush the water pipes with fresh water for 2 or 3 minutes. Do not use old water!
- Close the drainage valve.
- Spray the AKIMist®”E” for 2 or 3 minutes for flushing.
Also please check the AKIMist® maintenance manual for more tips:
Related articles
Stay updated: Ikeuchi news & insights
"*" indicates required fields
Get expert advice:
contact us today
Would you like to know what Ikeuchi can do for your organization? We’re happy to discuss your needs and show how we can solve your challenges. You’ll receive a response from us within 24 hours!
"*" indicates required fields
Call us: +31 (0) 20 820 2175
- Global presence and experience
- The number 1 nozzle manufacturer in Japan
- Japanese Precision Technology
“High quality nozzles. Friendly and helpful customer service”
“With Ikeuchi spray nozzles we are able to save costs as we don’t need to replace them so often as before.”
“When it is about nozzle technology, IKEUCHI are the experts. We always highly appreciated their knowhow and their extremely wide range of nozzles, not to mention their unrivalled AKIMist humidifier”
“When it is about nozzle technology, IKEUCHI are the experts. ”